TH-EC/LO-TFS

The remote control system TH-EC/LO is recommended for use in all types of locomotives and is compliant with the highest required safety standards SIL3 (EN 50128), SIL3 (EN 50129) and SIL3 (EN 61508) as well as the European Standard EN 50239 »Radio remote control system for traction vehicles and freight traffic«.

The transmitter of the remote control family TH-EC/LO with its ergonomic design is lightweight and easy to operate.

The transmitter TH-EC/LO-TFS is fitted with pushbuttons and switches for throttle-/brake commands.

The transmitter housing conforms to protection class IP65. System functions such as battery, transmitting and fault status are indicated via 3 LEDs.

Literature

TH-EC/LO Brochure 
TH-EC/LO Receiver Spare Parts 
TH-EC/LO Transmitter Spart Parts 


Standard Model Key Features

  • 1 key switch
  • 1 mushroom-head switch for stop-function
  • 2 pushbuttons for power control
  • 9 additional momentary or maintained switches
  • 1 buzzer - warning signal
  • 3 status LEDs
  • time division multiple access frequency management system for up to 5 systems simultaneously on one channel in the same area

Functions

Buttons/Switches for the following operations:

  • On/Off
  • Stop
  • Throttle/brake command switch
  • Direction back/forward
  • Train/locobrake selection
  • Assimilation
  • Pressure surge rapid charge
  • Locomotive bail off
  • Horn (also after active Stop)
  • Sand (also after active Stop)
  • Bell (also after active Stop)
  • Coupling back/forward
  • Tilt-time extension
  • Release after standstill

Customer specific options are available.

Receivers

19" Rack Version 

receiver 19 inch rack version

The remote control system TH-EC/LO is recommended for use in all types of locomotives and is in accordance with the highest safety standards in these application areas SIL3 (EN 50128), SIL3 (EN 50129) and SIL3 (EN 61508) as well as the European Safety Standards for controlling locomotives EN 50239.

The receiver electronics TH-EC/LO are housed in a 3 level 19"-rack version. Output commands wired to two connectors type DIN 41612 class »F«

The modular design which uses plug-in cards allow for easy access and a quick exchange of damaged components.

All received commands as well as the system status displays, can be read via the LEDs display; two 7 segment displays are externally visible.

Standard Model:

  • 2-channel dual microprocessor with failsafe monitoring
  • to execute manual and automatic STOP under SIL 3 according to EN 61508 for output commands depending on function SIL2 or SIL3 power pack 24VDC
  • separate output for manual stop and automatic emergency stop via 2 positive guided relays
  • commands via relays.For safety relevant functions (coupling) by dual positive guided relays
  • external visible status display via 7 segment plus 5 LEDs for each master/slave process
  • external visible LED display for all output commands
  • 3 plug-in slots
  • 16 bit address coding
  • Output commands wired to two connectors type DIN 41612 class »F«

Relays output cards: Optocoupler output cards, Analogue output cards and CANopen output cards are available.

 

Die Cast Housing 

receiver die cast housing

The remote control system TH-EC/LO is recommended for use in all types of locomotives and is in accordance with the highest safety standards in these application areas SIL3 (EN 50128), SIL3 (EN 50129) and SIL3 (EN 61508) as well as the European Safety Standards for controlling locomotives EN 50239.

The receiver TH-EC/LO housing is of die-cast aluminium and has IP65 classification. Output commands are wired to a multipin Harting type connector.

The modular design which uses plug-in cards allow for easy access and a quick exchange of damaged components.

All received commands as well as the system status displays, can be read via the LEDs display; two 7 segment displays are externally visible.

Standard Model:

  • 2-channel dual microprocessor with failsafe monitoring
  • to execute manual and automatic STOP under SIL 3 according to EN 61508 for output commands depending on function SIL2 or SIL3
  • power Pack 24VDC
  • separate output for manual stop and automatic emergency stop via 2 positive guided relays
  • commands via relays.For safety relevant functions (coupling) by dual positive guided relays
  • external visible status display via 7 segment plus 5 LEDs for each master/slave process
  • external visible LED display for all output commands
  • 2 plug-in slots
  • 16 bit address coding
  • Harting cable
  • classification IP65

Parallel to standard relays output cards: Optocoupler output cards, Analogue output cards and CANopen output cards are available.

Accessories

Batteries, Double-Pack
2 rechargeable NiCD-batteries, 1.6 Ah


theclo battery double pack 

Charger
With automatic processor controlled charging 24 V DC


theclo charger 
Carrying Bag
Made of durable Nylon with reflector strips and cushioned shoulder straps
theclo carrying bag 

Options

Operator vigilance device
The operator vigilance device can be selected via the transmitter software. It is an equivalent to the vigilance control system installed on the locomotive.

Unless the operator does not carry out actions on the transmitter at specific intervals of time (max. 30 seconds plus 7 seconds warning time) it is assumed that the operator is no longer controlling the locomotive with the necessary attention. In this case, the locomotive is brought to an immediate standstill by a rapid braking.

Feedback of engine status data
In addition to transmission of control signals from the transmitter to the receiver, data can also be transmit­ted from the locomotive back to the transmitter.

This can be e.g. speed of the locomotive, brake pressure, the set direction of travel or fault messages which is reported to the transmitter and can be displayed on a LCD.

LEDs and/or LCD show the operatro the needed information, at this the display of data can be custom­ized individually. Up to three lines with 3x12 charac­ters are displayed on the graphic-enabled LCD.

External transmitter antenna
External antennas can be required when the portable transmitter is operated at a fixed place, e.g. inside a control room of a loading station.

The transmitter can be designed in a way that the receiving signal is automatically switched from internal to external antenna when the transmitter is put in the cradle for the fixed operation.

TransLoop
This feature is based on most modern RFID- technology. External control commands can be transferred safely and contactless into the transmitter without the need for a switch or mechanical connector.

LED-flash lights
2 sets of 5 white and very bright LEDs can be mounted onto the transmitter front. A warning signal is generated by flashing these LEDs in a fast and alternate mode. This supports the shunting process with pushed trains especially at night operations by alerting people in the vicinity of an approaching pushed train.

Throttle / brake counter
The throttle / bake counter is a software function of the transmitter which allows a simple adaptation of time-depending to position depending throttle and brake commands.

Switch counter
The switch counter is a memory device, developed for transmitter and receiver of the TH-EC/LO. It allows counting and storing of numbers of cycles of the switches of the transmitter as well as the output relays of the receiver. A LED indicates to the operator when the life cycle limit of a switch has been reached. Simultaneously the information (limit reached) will be transmitted to the receiver from where it is transferred to the diagnostic memory circuit of the locomotive.

This is part of an optimum preventative maintenance program and reduces annual service costs by up to 50%.

Multiple transmitter operation (Pitch and Catch)
In addition to the normal 1 to 1 alignment between the transmitter and receiver, the receiver can also be controlled alternately by two different transmitters. For this purpose, each transmitter features a request and a release button to get control over the locomotive or for releasing the locomotive to pass the control to a second operator.

At any given time the locomotive can only be controlled by one operator. If one transmitter has already control over the locomotive, any request sent by the second transmitter is ignored and does not have any effect. The second transmitter is only able to control the locomotive after the first transmitter has released control over the locomotive.

This feature allows sharing the control over the locomotive, e.g. from a fixed transmitter at a loading station to a portable transmitter of an operator working in the yard.

Intrinsically safe
In accordance with the ATEX directive II 2G EEx ib IIC T4 the transmitters of the TH-EC/LO series can be manufactured for the use in hazardous zones with explosive atmospheres, category 2, zone 1

Contact Us

Location Phone Number

 
United States +1-724-962-3571
Email

mail@cattrongroup.com 


 
United States - Remtron +1-800-328-5570
Email

info@remtron.com 


 
Canada +1-514-908-1659 or +1-905-873-9440
Email

salescdn@cattrongroup.com 


 
Brazil +(55) 19-3243-7803
Email

vendas@cattron.com.br 


 
China +(86) 21-3120-0188
Email

saleschina@cattron.com 


 
UK +44-1-932-247511
Email

sales@cattronuk.com 


 
Germany +49-2161-6363-0
Email

info@theimeg.de 


 
Africa +27-11-425-1123
Email

Sales: salessa@lairdtech.com
Service: servicesa@lairdtech.com 

© 2013 Laird Technologies